POWER DISTRIBUTION

AC 120/240 Volt (60Hz)

Circuit Breaker Panels

Provides circuit protection for boats with

240 Volt AC systems

• 1168 Provides 1 spare rocker aperture

Component References

7372

1168

Style

Traditional Metal

360 Panel System

Total Positions

Main Only Main + 1 position

C-Series Circuit Breaker

1 Main, 50A (7287)

1 Main, 50A (7565)

Poles

3

3

Nominal Voltage

120/240V

120/240V

Maximum Voltage

240V AC

240V AC

Actuator Style

White Toggle

Flat Rocker

Width

in (mm)

5.25 (133.35)

4.88 (123.83)

Height

in (mm)

3.75 (95.25)

4.75 (120.65)

Depth

in (mm)

3.00 (76.20)

3.00 (76.20)

AC Residual Current Circuit Breaker Panels

GFCI Branch and ELCI Main

Reduces the risk of fire and shock hazards caused by defects in boat appliances and circuit wiring.

See page 80 for a review of new ABYC ELCI recommendations for AC Main circuit protection.

Features

• Provides Main circuit protection with branch circuits

1502

8100

1190

8101

Style

360 Panel System

Traditional Metal

360 Panel System

Traditional Metal

Total Positions

ELCI + 1 Position

ELCI

ELCI + 1 position

ELCI + 5 positions

GFCI/ELCI Circuit Breaker

1 - ELCI Main, 30A (3102)

1 - ELCI Main, 30A (3106)

1 - ELCI Main, 30A (3102)

1 - ELCI Main, 30A (3106)

A-Series Circuit Breaker

––

––

1 - Branch, 15A AC (7403)

2 - Branch, 15A (7210)

Amperage Trip Reference

30A

30A

30A

30A

Leakage Trip Amperage

30mA

30mA

30mA

30mA

Maximum Voltage

120V

120V

120V

120V

Actuator Style

Flat Rocker

White Toggle

Flat Rocker

White Toggle

Insulating Panel Back

1331 sold separately (p. 148)

––

1331 sold separately (p. 148)

––

Width x Height

in (mm)

4.88 (123.83) x 4.75 (120.65)

5.25 (133.35) x 3.75 (95.25)

4.88 (123.83) x 4.75 (120.65)

5.25 (133.35) x 7.50 (190.50)

Depth

in (mm)

3.99 (101.4)

3.50 (88.90)

3.99 (101.4)

3.50 (88.90)

8102

1193

Style

Traditional Metal

360 Panel System

Total Positions

ELCI + 2 positions

ELCI + 5 positions

ELCI Circuit Breaker

1 - ELCI Main, 30A AC (3106)

1 - ELCI Main, 30A AC (3102)

A-Series Circuit Breaker

2 - Branch, 15A AC (7210)

4 - Branch, 15A AC (7403)

Amperage Trip Reference

30A AC

30A AC

Leakage Trip Amperage

30mA

30mA

Maximum Voltage

120V AC

120V AC

Actuator Style

White Toggle

Flat Rocker

Insulating Panel Back

-

2 x 1331 sold separately (p. 148)

AC Meter

0–150V (9353)

-

Width x Height

in (mm)

5.25 (133.35) x 7.50 (190.50)

9.25 (234.95) x 4.75 (120.65)

Depth

in (mm)

3.50 (88.9)

3.99 (101.4)

Component References

• GFCI Branch and ELCI Main Circuit Breakers (p. 83)

• A-Series Circuit Breakers (p. 78-79)

• AC Analog Meters (p. 143)