Page Background bluesea.com

84

CIRCUIT PROTECTION AND SWITCHES

SMS Surface Mount System Panel Enclosure

Panel enclosure for ELCI Main circuit breakers and other

large frame devices. Meets ABYC E-11 when used with an

ELCI Main circuit breaker and mounted within 10 feet of

the shore power inlet

• Blank apertures for custom breaker loading

• Clear cover allows easy view of circuit breaker status

• Blank circuit positions accommodate Carling Technologies™

A and C Series Flat Rocker and ELCI Main circuit breakers

• Stainless steel mounting hardware included

Specifications

Enclosure Size

6.0" x 6.0" x 4.0"

152 mm x 152 mm x 102 mm

Exterior Overall Dimensions 7.6" x 7.4" x 4.7"

192 mm x 188 mm x 120 mm

Temperature Range

-40°C to 85°C

Cover Screws and Hardware 10-32 stainless steel

Mounting Hardware

Ø 1/4", #12, (6 mm)

Regulatory

IP66 – Protected against powerful water jets when cover is latched

Flammability rating – Per UL 508,

Toxicity – Non-toxic, halogen free, RoHS compliant

UL Listed and NEMA 4X rated, NEMA Type 4, 4X, 6, 6P, 12, and 13

See p. 160 for ABYC Interrupting Capacity Requirements.

NOTE: SMS panel enclosures are

pre-assembled and ready for wire

connections. Customers must select wire

and entry or exit locations, drill holes,

and install the appropriate glands.

3120

PN

3113

3116

3117

Description

6 blank circuit positions

ELCI Main + 3 blank circuit positions

120V AC ELCI 30A Dual

Circuit Breakers Installed

––

1 × ELCI Main 120V, 30A, 30mA (3102)

2 × ELCI Main 120V 30A, 30mA (3102)

Glands Included

––

2 × (3124) 3 × (3125)

2 × (3124) 4 × (3125)

LEDs Installed

––

4 × green ON indicating 120V AC (8034)

1 × red Reverse Polarity 120V AC (8066)

2 × green ON indicating 120V AC (8034)

2 × red Reverse Polarity 120V AC (8066)

Labels Included

30 Basic DC (4205)

30 Basic AC (4206)

Panel Voltage ID Labels

1 × AC Main, 1 Reverse Polarity

1 × ELCI, 30 Basic AC (4206)

Panel Voltage ID - 120V AC

Source Selection label Set - 10 labels

2 × Reverse Polarity, 2 ELCI

Panel Voltage ID - 120V AC

PN

3118

3119

3120

Total Positions

ELCI Main + 2 blank circuit positions ELCI Main + 1 blank circuit positions

ELCI Main + 2 blank circuit positions

Circuit Breakers Installed

1 × ELCI Main 120V 50A, 30mA (3103)

1 × ELCI Main 120/240V, 50A, 30mA (3104)

1 × ELCI Main 240V, 50A, 30mA (3093)

Glands Included

2 × (3124) 1 × (3125) 2 × (3126)

2 × (3124) 1 × (3125) 2 × (3126)

2 × (3124) 1 × (3125) 2 × (3126)

LEDs Installed

3 × green ON indicating 120V AC (8034)

1 × red “Reverse Polarity” 120V AC (8066)

3 × green ON indicating 120V AC (8034)

1 × red Reverse Polarity 120V AC (8066)

2 × green ON indicating 240V AC (6806)

Labels Included

1 × AC Main, 1 Reverse Polarity

1 × ELCI, 30 Basic AC (4206)

Panel Voltage ID - 120V AC

1 × AC Main, 1 Reverse Polarity

1 × ELCI, 30 Basic AC (4206)

Panel Voltage ID - 120V/240V AC

1 × AC Main, 1 ELCI

Panel Voltage ID - 240V AC